ERROR CODES
0x901, Hard SCSI Bus Error:
An abnormal SCSI bus or disk drive event was detected and could not be cleared through retry
operations.
0x903, Fan Shutdown-Removed:
A fan module has been shutdown or removed from the system.
0x904, VSC Shutdown-Removed:
A VCS (Power Supply) module has been shutdown or removed from the system.
0x905, Chassis Overtemperature:
A chassis over temperature condition has been detected, the SP will attempt corrective action.
0x906, Unit Shutdown:
The Unit, which this drive is a member of, has been shutdown and can no longer be accessed by the
host.
0x907, Controller Firmware Panic:
This SP's firmware encountered a situation from which there was no reliable execution other than
to reload itself from disk and restart. This message is logged once the restarted session
completes its initialization.
0x908, Hardware Fault - Cache Disabling:
Some hardware condition has caused the controller to disable the cache.
0x909, Cache Dump Failure:
The SP cannot safely dump the cache to disk. This will usually be caused by one ore more of the
cache dump disk drives being missing or failed.
0x90A, Assign fails - Cache Dirty Unit:
The SP cannot assign this unit, because it is marked as having cached data outstanding, and the
SP has no access to the data.
0x90B, Controller Cannot Initialize Cache:
There was some hardware or software failure which occurred when the SP attempted to initialize a new
cache image.
0x90C, Cache Image Exceeds Memory Size:
This controller is incapable of loading the saved cache data image due to insufficient cache memory
size.
0x90D, BBU Removed:
The BBU in this system has failed or been removed.
0x90E, BBU Failed:
The BBU in this system has failed its internal selftest.
0x90F, Cache Recovered with Errors:
The attempted cache recovery on this SP recovered the dirty cache pages for some, but not all, of
its dirty units.
0x910, Cache Recovery Failed:
The attempted cache recovery on this SP failed to recover the pages for any of its cache dirty
units.
0x920, Hard Media Error:
This disk CRU has reported a media defect which could not be successfully cleared by the SP. This
is a hard media error.
0x921, Host vault load failed:
The SP encountered multiple errors while attempting to load the cache image from disk.
This message may indicate multiple drive failures.
0x922, Host vault load inconsistent:
The SP found the cache image on disk to have inconsistent data. This may indicate a failure or
abort of the cache dump.
0x923, Host vault load failed bitmap ok:
The SP successfully read the control portion of the cache images on disk, but found the data
portion to be incomplete. This means that a failure or abort occurred during the cache dump.
0x924, Host vault disks scrambled:
The SP found the vault drives containing the cache image to be in different order than when the cache
images was dumped to disk. The drives must be restored to their original order before the SP can
load the cache image.
0x925, Single Board Cache; Need PROM Update:
This SP, which is operating in non-mirrored caching modem has too low a PROM revision level.
Write Caching cannot be enabled.
0x926, RAID-3 Unit Cannot Assign, No Memory:
A RAID-3 LUN cannot be enabled because memory allocated for RAID-3 processing is not available
(that is, the memory has been removed or reconfigured).
0x928, RAID-3 Initialization Failure - No Memory:
No RAID-3 LUNs can be enabled because memory allocated for RAID-3 processing is not available
(this is, the memory has been removed or reconfigured).
0x929, Front End Fibre Link Down:
0x930, PCMCIA Card Write Protected While Active:
The PCMCIA (write-cache memory) card is write protected.
0x931, PCMCIA Card Battery Failed:
The PCMCIA (write-cache memory) card's battery failed. You must replace the battery.
0x932, PCMCIA Card Absent or Inserted Incorrectly:
The PCMCIA (write-cache memory) card is not present or was inserted incorrectly.
0x933, PCMCIA Card Post Test Failed:
The PCMCIA (write-cache memory) card failed its powerup (POST) test. The SP disabled storage-
system write caching. Power down the storage system, replace the card, and power up the storage
system.
0x934, PCMCIA Card Doesn't Match Subsystem, Cache Data Locked:
The PCMCIA (write-cache memory) card was used in a different storage system. The SP has locked the card to prevent cache data from being overwritten. You must either remove the card and installed it in the correct storage system or clear the card.
0x935, PCMCIA Card too small for currently configured write cache:
The PCMCIA (write-cache memory) card's capacity is smaller than the specified size of the SP's write cache. The SP disabled storage-system write
caching. You must either re-specify the write cache size to equal the card's capacity or install a card with a capacity that equals the specified size.
0x936, PCMCIA Card Hardware Failure:
The SP encountered a hardware failure while trying to write to the SP. The SP has disabled write caching.
0x937, Command Failed:
A command failed for the reason explained in the extended status word.
0x938, Non R3 LUN-Can't Assign BW:
Only RAID-3 Units or hot spares can be assigned in a system optimized for Raid 3 Bandwidth.
FATAL ERROR CODES
0xA02, Failed SCSI Bus:
A SCSI channel has failed, all drives on that bus are now inaccessible by the controller.
0xA05, NONVRAM Uninitialized:
The non-volatile memory on this SP was found to be uninitialized. The SP has reinitialized the
memory to its default state, and the SP will be functional after a reboot.
0xA06, Chassis Shutdown:
An over-temperature situation could no be corrected. All drives in the chassis will be
shutdown.
0xA07, Drive Failure:
The disk drive has failed and can no longer be accessed.
0xA08, Database Sync Error:
The SP cannot determine that correct logical configuration of all units in the system. Some
units may be unusable.
0xA09, Drive Too Small:
A replacement drive have been inserted and does not have adequate capacity for a rebuild operation
to begin.
0xA11, Peer Controller Removed:
This SP's peer is no longer responding to queries from this SP following a period of time where the
peer was known present.
0xA12, Cache Memory Hard Error:
This SP, which is operating in non-mirrored caching mode, has detected a non-recoverable
memory fault in the cache memory area.
0xA13, CRU Type Unsupported:
This type of disk CRU is not supported by the current SP software. The disk cannot be bound or
used for host I/O.