ERROR CODES

0x901, Hard SCSI Bus Error:
An abnormal SCSI bus or disk drive event was detected and could not    be cleared through retry
operations.

0x903, Fan Shutdown-Removed:
A fan module has been shutdown    or removed from    the system.

0x904, VSC    Shutdown-Removed:
A VCS (Power Supply) module has been shutdown or removed from the system.

0x905, Chassis Overtemperature:
A chassis over    temperature condition has been detected, the SP will attempt corrective action.

0x906, Unit Shutdown:
The Unit, which this drive is a member    of, has been shutdown and can no longer be accessed by    the
host.

0x907, Controller Firmware    Panic:
This SP's firmware encountered    a situation from which there was no reliable execution other than
to reload itself from disk and    restart. This message is logged once    the restarted session
completes its initialization.

0x908, Hardware Fault - Cache Disabling:
Some hardware condition has caused the    controller to disable the    cache.

0x909, Cache Dump Failure:
The SP    cannot safely dump the cache to    disk. This will usually be caused    by one ore more    of the
cache dump disk drives    being missing or failed.

0x90A, Assign fails - Cache Dirty Unit:
The SP    cannot assign this unit, because it is marked    as having cached data outstanding, and the
SP has    no access to the data.

0x90B, Controller Cannot Initialize Cache:
There was some    hardware or software failure which occurred when the SP attempted    to initialize a    new
cache image.

0x90C, Cache Image    Exceeds    Memory Size:
This controller is incapable of loading the saved cache data image due to insufficient cache memory
size.

0x90D, BBU    Removed:
The BBU in this system    has failed or been removed.

0x90E, BBU    Failed:
The BBU in this system    has failed its internal selftest.

0x90F, Cache Recovered with Errors:
The attempted cache recovery on this SP recovered the dirty cache pages for some, but not all, of
its dirty units.

0x910, Cache Recovery Failed:
The attempted cache recovery on this SP failed    to recover the pages for any of its cache    dirty
units.

0x920, Hard Media Error:
This disk CRU has reported a media defect which could not be successfully cleared by the SP. This
is a hard media error.

0x921, Host vault load failed:
The SP    encountered multiple errors while attempting to load the    cache image from disk.
This message may indicate multiple drive failures.

0x922, Host vault load inconsistent:
The SP    found the cache    image on disk to have inconsistent data. This may indicate a failure or
abort of the cache dump.

0x923, Host vault load failed bitmap ok:
The SP    successfully read the control portion of the cache images on disk, but found the data
portion to be incomplete. This means that a failure or abort occurred during the cache dump.

0x924, Host vault disks scrambled:
The SP    found the vault    drives containing the cache image to be in    different order    than when the cache
images    was dumped to disk. The drives    must be restored to their original order before the SP    can
load the cache    image.

0x925, Single Board Cache;    Need PROM Update:
This SP, which    is operating in    non-mirrored caching modem has too low a PROM revision level.
Write Caching cannot be enabled.

0x926, RAID-3 Unit    Cannot Assign, No Memory:
A RAID-3 LUN cannot be    enabled    because    memory allocated for RAID-3 processing is not    available
(that is, the memory has been removed or reconfigured).

0x928, RAID-3 Initialization Failure - No Memory:
No RAID-3 LUNs    can be enabled because memory allocated for RAID-3 processing is not    available
(this is, the memory has been removed or reconfigured).

0x929, Front End Fibre Link Down:

0x930, PCMCIA Card    Write Protected    While Active:
The PCMCIA (write-cache memory) card is write protected.

0x931, PCMCIA Card    Battery    Failed:
The PCMCIA (write-cache memory) card's    battery failed. You must replace the battery.

0x932, PCMCIA Card    Absent or Inserted Incorrectly:
The PCMCIA (write-cache memory) card is not present or was    inserted incorrectly.

0x933, PCMCIA Card    Post Test Failed:
The PCMCIA (write-cache memory) card failed its powerup (POST)    test. The SP disabled storage-
system    write caching.    Power down the storage system, replace the card, and power up    the storage
system.

0x934, PCMCIA Card    Doesn't    Match Subsystem, Cache Data Locked:
The PCMCIA (write-cache memory) card was used in a different storage system. The SP has locked    the card to prevent cache data from being overwritten. You must    either remove the card and installed it in the correct storage system or clear the card.

0x935, PCMCIA Card    too small for currently    configured write cache:
The PCMCIA (write-cache memory) card's    capacity is smaller than the specified size of the    SP's write cache.     The SP    disabled storage-system    write
caching. You must either re-specify the write cache size to equal the card's    capacity or install a card    with a capacity    that equals the    specified size.

0x936, PCMCIA Card    Hardware Failure:
The SP    encountered a hardware failure while trying to write to the SP. The SP has disabled write caching.

0x937, Command Failed:
A command failed for the reason explained in the extended status word.

0x938, Non    R3 LUN-Can't Assign BW:
Only RAID-3 Units or hot spares can be    assigned in a system optimized for    Raid 3 Bandwidth.

FATAL ERROR CODES

0xA02, Failed SCSI    Bus:
A SCSI    channel    has failed, all    drives on that bus are now inaccessible by the controller.

0xA05, NONVRAM Uninitialized:
The non-volatile memory on this SP was    found to be uninitialized.     The SP    has reinitialized the
memory    to its default state, and the SP will be functional after a reboot.

0xA06, Chassis Shutdown:
An over-temperature situation could no    be corrected. All drives    in the chassis will be
shutdown.

0xA07, Drive Failure:
The disk drive    has failed and can no longer be accessed.

0xA08, Database Sync Error:
The SP    cannot determine that correct logical configuration of all units in the system. Some
units may be unusable.

0xA09, Drive Too Small:
A replacement drive have been inserted    and does not have adequate capacity for    a rebuild operation
to begin.

0xA11, Peer Controller Removed:
This SP's peer    is no longer responding    to queries from this SP following    a period of time where the
peer was known    present.

0xA12, Cache Memory Hard Error:
This SP, which    is operating in    non-mirrored caching mode, has detected a non-recoverable
memory    fault in the cache memory area.

0xA13, CRU    Type Unsupported:
This type of disk CRU is not supported    by the current SP software. The disk    cannot be bound    or
used for host I/O.